What was found
FWD ENTRY EMERGENCY EXIT SLIDE LIGHT INOP<[01] REPLACED LAMP AT FWD ENTRY EMERGENCY EXIT SLIDE LIGHT IAW AMM 33-51-04-960-801; LIGHT CONTINUE INOP.;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] RECONNECTED FWD ENTRY EMERGNCY EXIT SLIDE LIGHT CONNECTOR AND PERFORMED GOOD FUNCTIONAL TEST PER AMM 33-51-04-960-801 STEP D (4).;[04] VERIFIED ACTION ITEM 3;[05] UPDATED MEASUREMENTS TABLE.;[06] VERIFIED CORRECTIONS ITEMS 3-5;[07] VERIFIED CORRECTIVE ACTION COMPLETE.<BR>VERIFIED MEASUREMENT TABLE.