What was found
CRACK FLOOR BEAM LOCATED STA 294.5 AND RBL 52 AT FWD GALLEY AREA 2024-253238<[01] TOOL USED ON STEP 7;8 AND 9. EDDY CURRENT EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101V022235; DUE DATE: 07-SEP-24;[02] TOOL USED: TEMPERATURE CONTROLLER P/N P3015GOES00000 S/N 142811019 DUE DATE 23 JAN 25; P/N P3015GOES00000 DUE DATE 142811020 DUE DATE 23 JAN 25.;[03] TOOL USED: RADIOMETER PHOTOMETER; P/N: XRP-3000; S/N: 1859843; DUE DATE: 24-JUL-24.;[04] REPAIRED FLOOR BEAM LOCATED STA 294.5 AND BTW RBL15 TO RBL55 FWD GALLEY AREA IAW SRM B737-700 53-10-51-2R-16 REPAIR 16 ALTERNATIVE 2 AND DRAWING# 141A5502 SHEET 15 REV .-SEE INDIVIDUAL SIGN OFFS BELOW.;[05] TASK COMPLETED; RII <BR>SEE INDIVIDUAL SIGN OFFS BELOW