What was found
CRACK ON STUB FRAME LOCATED STA 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA 2024-253242<[01] TOOL USED ON STEP 4 AND STEP 5; EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600; S/N: 60007161486; DUE DATE: 28-JUL-24;[02] PERFORMED REPAIR ON STUB FRAME LOCATED STA 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA I.A.W B737-700 SRM 53-10-15-2R-7 AND DWG 141A8430 SHEET 4 REV B. SEE INDIVIDUAL SIGN OFF BELOW.;[03] PERFORMED REPAIR ON STUB FRAME LOCATED STA 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA I.A.W B737-700 SRM 53-10-15-2R-7 AND DWG 141A8430 SHEET 4 REV B. SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII CERTIFIED