What was found
AFT GALLLEY FLOOR STRUCTURE STA. 947; LBL 52 HAS CORROSION AROUND LAV MOUNT.<[01] REMOVE DAMAGE IAW SRM 51-40-02. REWORKED ARE REMAINING THICKNESS IS OUT OF LIMIT PER SRM 53-70-51-1A-1 FIG 104 DETAIL E.;[02] REMOVED LAV. MOUNT INTERCOSTAL @LBL 52; FLOOR SUPPORT AT STA. 947+5; FLOOR SUPPORT AT LBL 52 TO F.O.M IAW SRM 51-40-02.;[03] REMOVED CORROSION DAMAGED IAW SRM 53-70-51-2R-8 REPAIR 8 ALT. 3 FIG. 205;[04] REMOVED CORROSION DAMAGED IAW SRM 53-70-51-2R-8 REPAIR 8 ALTERNATIVE 3 FIG. 205. REMAINING THICKNESS IS 0.155;[05] RII. VERIFIED CORROSION REMOVAL REF SRM 53-70-51-2R-8 REPAIR 8 ALTERNATIVE 3 FIG. 205. VERIFIED REMINING THICKNESS IS 0.155. SIGN OFF FOR CORRECTIVE ACTION #4 ONLY.;[06] FABRICATED AND DRILLED SHIM IAW SRM 53-70-51-2R-8 REPAIR 8 ALTERNATIVE 3 FIG. 205. OK TO TREAT AND PAINT.;[07] INSPECTED WORK PERFORMED ON C/A #6;[08] TREATED AND PAINTED SHIM AND BLENDED AREA PER AMM 51-21-41 AND 51-21-72. OK TO INSTALL.;[09] INSPECTED WORK PERFORMED ON C/A #8;[10] INSTALLED SHIM IAW SRM 53-70-51-2R-8 REPAIR 8 ALTERNATIVE 3 FIG. 205. OK TO REINSTALL LAV MOUNT AND INTERCOSTAL.;[11] INSPECTED WORK PERFORMED ON C/A #10