What was found
AFT CARGO COMPARTMENT STA 767 THRU STA 787 RBL 21 TRANSITION ANGLE HAS NUMEROUS CORROSION AREAS MARKED<[01] REMOVED CORROSION PER SRM 53-60-15-1A-1 (0.044' REMAINING THICKNESS). SHIELD (TRANSITION ANGLE) IS OUT OF LIMITS PER SRM 53-60-15-1A-1.;[02] DRILL AND COUNTERSUNK NEW SHIELD IAW SRM 51-40-05 AND SRM 51-40-08.;[03] NEED OK TO INSTALL NEW SHIELD.;[04] INSTALLED NEW TRANSITION ANGLE (SHIELD) IAW SRM 51-40-02.;[05] OKAY TO INSTALL NEW SHIELD.;[06] C/W C.A. STEP 4 (AMT T. GEBREMARIAM) OF THE INSTALLATION OF NEW TRANSITION ANGLE (SHIELD) AT STA 767 THRU STA 787 RBL 21. RII