What was found
FWD CARGO THRESHOLD WEB UPPER SURFACE HAS NUMEROUS AREAS OF CORROSION AT N/P AND FASTNER HOLES. STA 440 - 492 RBL 29-30 WL 156. MRKD<[01] BLENDED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF LIMITS PER SRM 53-30-15-1A-1;[02] C/W INSP. BLENDED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF LIMITS PER SRM 53-30-15-1A-1;[03] REMOVED THRESHOLD WEB PER SRM 51-40-02.;[04] DRILLED AND COUNTERSUNK NEW WEB IAW SRM 51-4-05 AND SRM 51-40-08.;[05] INSPECTED WORK ACCOMPLISHED IN C/A #S<BR>3. ROSS RICHARDSON (TECHNICIAN); 03-MAY-2024 00:38 UTC<BR>REMOVED THRESHOLD WEB PER SRM 51-40-02.<BR><BR>4. TEKLU GEBREMARIAM (TECHNICIAN); 03-MAY-2024 08:51 UTC<BR>DRILLED AND COUNTERSUNK NEW WEB IAW SRM 51-4-05 AND SRM 51-40-08.;[06] PRIMED COUNTERSINKS AND NEW HOLES PER AMM 51-21-72. INSTALLED NEW NUT PLATES PER SRM 51-40-02. OK TO INSTALL WEB.;[07] INSPECTED AS REQUIRED. CORRECTIVE ACTION #6. OK TO INSTALL NEW WEB.;[08] INSTALLED NEW WEB PER SRM 51-10-02 AND 51-40-02.;[09] INSPECTED AS REQUIRED. CORRECTIVE ACTION #8