What was found
FWD CARGO L/H TRANSITION ANGLE UPPER SURFACE HAS CORROSION AT N/P AND FASTNER HOLES STA 500B - 500C LBL 23-25 WL 156. MRKD<[01] REMOVED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] C/W INSP. REMOVED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF LIMITS PER SRM 53-00-53-1A-2.;[03] REMOVED AND REPLACED TRANSITION ANGLE ASSEMBLY FROM STA 400 TO STA 500I I.A.W SRM 51-40-02.;[04] REMOVED AND REPLACED TRANSITION ANGLE ASSEMBLY FROM STA 400 TO STA 500I I.A.W SRM 51-40-02.;[05] REMOVED AND REPLACED TRANSITION ANGLE ASSEMBLY FROM STA 400 TO STA 500I I.A.W SRM 51-40-02.