What was found
FWD CARGO L/H TRANSITION ANGLE UPPER SURFACE HAS CORROSION AT N/P AND FASTNER HOLES STA 500 - 500A LBL 23-25 WL 156. MRKD<[01] REMOVED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] C/W INSP. REMOVED CORROSION PER SRM 51-10-02. BLENDED AREA OUT OF LIMITS PER SRM 53-00-53-1A-2.;[03] DISPLACED LH FWD BLKHEAD ATTACHED RAIL AT STA. 400 TO F.O.M IAW SRM 51-40-02.;[04] REMOVED LH TRANSITION PANEL ASSY. FROM STA. 400 TO STA. 500I IAW SRM 51-40-02.;[05] REMOVED AND REPLACED TRANSITION ANGLE ASSEMBLY FROM STA 400 TO STA 500I I.A.W SRM 51-40-02.;[06] REMOVED AND REPLACED TRANSITION ANGLE ASSEMBLY FROM STA 400 TO STA 500I I.A.W SRM 51-40-02.