As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FWD ENTRY DOOR MOP SILL CRACKED ON VERTICAL FLANGE AT BS 303 LBL 58 WL 208.<[01] CRACK ON FED ENTRY DOOR MOP SILL EXCEED LIMITS GIVEN IN THE SRM; FOUND TO BE OUT OF LIMITS. REMOVED; REPLACED AND INSTALLED NEW FED MOP SILL PER SRM 53-10-15-1A-1; SRM 51-10-02-0G-0; SRM 51-40-05-0G-0; SRM 51-40-02-0G-0 AND DWG 141A8110.;[02] VERIFIED CORRECTIVE ACTION ITEM 1; CARD COMPLETE.