What was found
CRACK ON CLIP ANGLE LOCATED BS 400 AT LEVEL STR 26L AT FWD CARGO COMPARTMENT 2024-269965<[01] REPLACED CLIP ANGLE AND FASTENERS LOCATED ON BS 400 AT LEVEL STR 26L AT FWD CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 TEM 9 AND DRAWING 143A7505 SHEET 2 REV B. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED CLIP ANGLE AND FASTENERS LOCATED ON BS 400 AT LEVEL STR 26L AT FWD CARGO COMPARTMENT IAW B737-700 SRM 51-10-02 TEM 9 AND DRAWING 143A7505 SHEET 2 REV B. VERIFIED