What was found
CRACK ON STUB FRAME LOCATED BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA 2024-270002<[01] NEW STUB FRAME; DEPRESSOR; STOP FITTING AND FASTENERS. LOCATED BS 294.5 BTW STR14R TO STR 17R AT FWD GALLEY AREA ANDIAW B737-700 SRM 51-10-02 STEP 9 AND SRM 51-40-02. DWG 141A8370 SHEET 10 REV D. SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED STUB FRAME LOCATED BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A8370 SHEET 10 REV: D SEE INDIVIDUAL SIGN OFF BELOW.;[03] CORRECTED STEP 2: REPLACED STUB FRAME LOCATED BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DWG 141A8370 SHEET 10 REV: D SEE INDIVIDUAL SIGN OFF BELOW.;[04] RII COMPLETED JOB