What was found
AFT GALLEY L/H FWD FLOOR MOUNT HAS POSSIBLE LIGHT CORROSION PRESENT AROUND LOWER O/B EDGE. REMOVED DAMAGE PER SRM 51-10-02. DAMAGE FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. MEASURES 0.010 DEEP. REMOVED L/H AFT SHEAR WEB PER SRM 51-40-02. LOCATED AND DRILLED NEW WEB PER SRM 51-40-05. TREATED AND PRIMED OPEN HOLES AND BARE METAL ON NEW WEB AND AIRCRAFT STRUCTURE PER SRM 51-20-01. INSTALLED NEW WEB, PRIMED ALL FASTENER HEADS, AND APPLIED FILLET SEAL PER SRM 51-40-02. LOCATED AND DRILLED NEW WEB PER SRM 51-40-05. TREATED AND PRIMED OPEN HOLES AND BARE METAL ON NEW WEB AND AIRCRAFT STRUCTURE PER SRM 51-20-01. INSTALLED NEW WEB; PRIMED ALL FASTENER HEADS; AND APPLIED FILLET SEAL PER SRM 51-40-02