What was found
AFT GALLEY FLOOR STRUCTURE SUPPORT ANGLE AT STA 986.5 +8' APPROXIMATELY 12' I/B OF AFT SERVICE DOOR OPENING HAS SMALL AREA OF SURFACE CORROSION ON FASTENER HOLE. REMOVED CORROSION PER SRM 53-70-51-1A-1. FOUND TO BE OUT OF LIMITS. BLENDED CORROSION ON AFT GALLEY STRUCTURE SUPPORT ANGLE PER SRM 51-10-02. REMAINING THICKNESS 0.035. DAMAGE REMOVAL IS OUT OF LIMITS PER SRM 53-70-51-1A-1. REMOVED SUPPORT ANGLE FOR REPLACEMENT PER SRM 51-40-02. VERIFIED OUT OF LIMITS PER SRM 53-70-51-1A-1. LOCATED, DRILLED, COUNTERSUNK, AND DEBURRED REPLACEMENT SUPPORT ANGLE PER SRM 51-40-05 AND SRM 51-40-08. LOCATED, DRILLED, COUNTERSUNK, AND DEBURRED REPLACEMENT SUPPORT ANGLE PER SRM 51-40-05 AND SRM 51-40-08. INSTALLED NEW SERVICEABLE AFT GALLEY FLOOR STRUCTURE SUPPORT ANGLE PER SRM 51-40-02. INSTALLED NEW SERVICEABLE AFT GALLEY FLOOR STRUCTURE SUPPORT ANGLE PER SRM 51-40-02.