What was found
CRACK INDICATION FOUND IN OPEN HOLE LOC ON BS 727 INNER CHORD AT STRINGER 18A LEFT SIDE; CRACK DIRECTION IS: 2 O CLOCK( VIEW LOOKING INSIDE TO OUTSIDE) 2024-270318<[01] ON STEP 2. TOOL USED: ET INSTRUMENT. P/N: NORTEC 600D. S/N: 210136503. DUE DATE: 23-MAY-24.;[02] TOOLS USED: TEMPERATURA CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 23-JAN-25; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 23-JAN-25.;[03] CORRECTED STEP 2. TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 23-JAN-25; TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 142811019; DUE DATE: 23-JAN-25.;[04] TOOL USED DIGITAL CALIPER P/N: 500-193-30 S/N: 0000291 DUE DATE: 01-NOV-24.;[05] REPAIRED INNER CHORD BSTA 727 AND AT S-18A LHS IAW EA# 24-153-01268-WIP1; 24-153-01268-WIP2; 24-153-01268-WIP3; 24-153-01268-WIP4 AND EA#24-153-01268; SEE INDIVIDUAL SIGNOFF BELOW.;[06] REPAIRED INNER CHORD BSTA 727 AND AT S-18A LHS IAW EA# 24-153-01268-WIP1; 24-153-01268-WIP2; 24-153-01268-WIP3; 24-153-01268-WIP4 AND EA#24-153-01268; SEE INDIVIDUAL SIGNOFF BELOW. COMPLETED RII