What was found
AFT L/H LAV; O/B AFT FLOOR MOUNT AT STA 947 HAS AREAS OF SURFACE CORROSION. REMOVED CORROSION IAW SRM 51-10-02. DAMAGE REMOVAL .041' OUT OF LIMITS PER SRM 53-70-51-1A-1 REMAINING THICKNESS ON 947.5 FLOORBEAM. REMOVED AFT L/H LAV; O/B AFT FLOOR MOUNT AT STA 947 IAW SRM 51-40-02. UPON FURTHER INSPECTION; FOUND AREA REPAIRABLE PER SRM 53-70-51-2R-8. ACCOMPLISHED BLENDOUT FOR SHIM PER SRM 53-70-51-2R-8. MAX MATERIAL REMAINING 0.136. MATERIAL REMOVAL IS WITHIN LIMITS PER SRM 53-70-51-2R-8. FLAP PEENED REMOVAL AREA PER SRM 53-70-51-2R-8 AND SOPM 20-10-03. FABRICATED, DRILLED, & DEBURRED 0.040. SHIM SRM 53-70-51-2R-8 ALTERNATIVE 3. FABRICATED, DRILLED, & DEBURRED 0.040? 7075-T6 SHIM PER SRM 53-70-51-2R-8 ALTERNATIVE 3. FABRICATED ON CA36 PER SRM 53-70-51-2R-8 ALTERNATIVE 3. INSTALLED REPAIR SHIM PER SRM 53-70-51-2R-8 ALTERNATIVE 3. REINSTALLED AFT L/H LAV, O/B AFT FLOOR MOUNT AT STA 947 IAW SRM 51-40-02. INSTALLED REPAIR SHIM PER SRM 53-70-51-2R-8 ALTERNATIVE 3. REINSTALLED AFT L/H LAV; O/B AFT FLOOR MOUNT AT STA 947 IAW SRM 51-40-02.