What was found
CORROSION AROUND FITTING ON FLOOR BEAM BS 947; LBL 25 (MARKED)<[01] REMOVED DAMAGE ON BS 947 LBL 25 FLOOR BEAM UPPER SURFACE IN AN AREA OF 1'X 1'; ORIGINAL THICKNESS IS 0.180' REMAINING THICKNESS IS 0.105' CORROSION FOUND TO BE OUT OF LIMITS I.A.W SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 PAR.4.D(2)(A) FIG.104/ALLOWABLE DAMAGE 1 DETAIL C. FLOOR BEAM UPPER SURFACE TO BE REPAIR IN CUSTOMER CARD NBR: TTG8Q00T88KY I.A.W SRM 53-70-51-2R-5 REPAIR 5 ALTERNATIVE 1.<BR>TOOL USED ID: ATS2472 DUE: 12/2024.;[02] VERIFIED CORRECTIVE ACTION 1.