What was found
CORROSION FLOOR STRUCTURE FITTING LOCATED BS 947; LBL 49; WL 208.1 AT AFT GALLEY AREA 2024-318126<[01] TOOL USED: ULTRASONIC THICKNESS GAGE; P/N: 45 MG; S/N: 130066701; DUE DATE: 09-JUN-24.;[02] REPLACED INTERCOSTAL LOCATED BS 947 T0 967; LBL 49; WL 208.1 AT AFT GALLEY AREA IAW B737-800 SRM 51-40-02 AND DWG 147A5650 SHETTS 55 REV A;[03] REPLACED INTERCOSTAL LOCATED BS 947 T0 967; LBL 49; WL 208.1 AT AFT GALLEY AREA IAW B737-800 SRM 51-40-02 AND DWG 147A5650 SHETTS 55 REV A;[04] CORRECTED CORRECTIVE ACTION 3 <BR><BR>REPLACED INTERCOSTAL LOCATED BS 947 T0 967; LBL 49; WL 208.1 AT AFT GALLEY AREA IAW B737-800 SRM 51-40-02 AND DWG 147A5650 SHETTS 55 REV A<BR><BR>ITEM RII