As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
HORIZONTAL LOWER BEAM STA 1088 HAS THE -3 SHIM WITH FEW RIVET HOLES ELONGATED.<[01] COMPLETED FABRICATION OF REPAIR SHIM; MATERIAL: 0.010-INCH 2024-T3 CLAD SHEET PO#1685376 PER EA24-153-01328 WIP 2 STEP 5.<BR>SURFACE ROUGHNESS GUAGE B/C 171854 NO CAL DUE AND TREATED AND PRIMED SHIM PER REF AMM 51-21-41-370-803; AMM 51-21-72-370-804 LOWER BEAM STA 1088.;[02] VERIFIED STEP 1.