What was found
CORROSION ON FLOOR BEAM AT AFT WET AREA BS986 RBL43 WL208. MARKED<[01] REMOVED AND REPLACED REPAIR PARTS PER SRM 51-40-02 AS SHOW IN SWA EA# 1-753-33013 REV IR;[02] VERIFIED ALL STEPS AND CORRECTIVE ACTION ITEMS; CARD COMPLETE.;[03] VERIFIED ALL STEPS AND CORRECTIVE ACTION ITEMS; CARD COMPLETE.