What was found
CUSTOMER REQUEST CRACK ON EXTERNAL GROUND ELECTRICAL POWER RECEPTACLE SURROUND DOUBLER ZONE 2 LOWER FUSELAGE 2024-339858<[01] TOOL USED: EDDY CURRENT EQUIPMENT P/N NORTEC 500D S/ N 500X1693P030457 DUE DATE: 15-OCT-24.;[02] TOOL USED ON STEP 8 ET EQUIPMENT: P/N: NORTEC 600D; S/N: 220272512; CAL DUE DATE: 08-JAN-25;[03] PERFORMED PERMANENT REPAIR ON EXTERNAL GROUND ELECTRICAL POWER RECEPTACLE SURROUND DOUBLER ZONE 2 LOWER FUSELAGE IAW B737-800 SRM 53-10-15-2R-4 REPAIR-4 ALTERNATIVE 2 FIGURE 204 ZONE 2 SHEET 3 TO 4 AND SRM 51-40-02 SEE INDIVIDUAL SIGN OFF BELOW;[04] PERFORMED PERMANENT REPAIR ON EXTERNAL GROUND ELECTRICAL POWER RECEPTACLE SURROUND DOUBLER ZONE 2 LOWER FUSELAGE IAW B737-800 SRM 53-10-15-2R-4 REPAIR-4 ALTERNATIVE 2 FIGURE 204 ZONE 2 SHEET 3 TO 4 AND SRM 51-40-02 <BR>RII ACCOMPLISHED <BR>SEE INDIVIDUAL SIGN OFF BELOW