What was found
CRACK INDICATION ON HORIZONTAL PRESSURE DECK WEB RBL 41 STA 663 AT PASSENGER CABIN (1E/A). CRACK LENGTH APPROX. 0.312 INCH 2024-295270<[01] TOOL USED ON STEP 6 AND 7 EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 60009161631; DUE DATE:11-MAR-25.;[02] PERFORMED PERMANENT REPAIR ON PRESSURE DECK WEB LOCATED RBL 30 TO RBL 60; STA 663.75 TO STA 675 AT PASSENGER CABIN. IAW B737-700 SRM 53-40-51-2R-2 REPAIR 2 FIG 203; SEE INDIVIDUAL SIGN OFF BELOW.;[03] PERFORMED PERMANENT REPAIR ON PRESSURE DECK WEB LOCATED RBL 30 TO RBL 60; STA 663.75 TO STA 675 AT PASSENGER CABIN. IAW B737-700 SRM 53-40-51-2R-2 REPAIR 2 FIG 203; SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII