What was found
FIXED UPPER TRAILING EDGE PANEL 651CT, HAS LOOSE HARDWARE; WORN MOUNTS & SERRATIONS. CW HIGH FREQUENCY EDDY CURRENT (HFEC) INSPECTION ALONG THE CUT EDGES & HOLES REF NDT PART 6, 51-00-00; PROCEDURE 23 & NDT PART 6, 51-00-00, PROCEDURE 16, NO DEFECTS NOTED. REMOVED OTBD & INBD DEFLECTION RIB SERRATED PLATES. TRIMMED DEFLECTION RIB VERTICAL FLANGE AS REQUIRED. WORK PERFORMED IAW SRM 57-51-02-2R-4. PERFORMED STEPS A, B, C, D, E, & F IAW SRM 57-51-02-2R-3. ACCOMPLISHED HFEC OF REPAIR AREA IAW STEP G OF SRM 57-51-02-2R-3. IAW NDT PART 6, 51-00-00; PROCEDURE 23. NO DEFECTS NOTED. COMPLIED WITH SRM REPAIR 57-51-02-2R-3, REPAIR 3 THRU STEP 4. L. (6) & STEP 4. M.3. FABRICATED REPAIR PARTS, PRIMED, SEALED, & TEMP IN PLACE. COMPLIED WITH SRM REPAIR 57-51-02-2R-3; REPAIR 3 THRU STEP 4.L.(6) & STEP 4.M.(3).