What was found
MAIN CABIN WING CENTER SECTION FLOOR PANEL 231YF CRACKED AT AFT END MKD DOT<[01] PERFORMED DRY OUT; PREPARED DAMAGE AREA AND APPLIED PERMANENT REPAIR ON PANEL#231YF AS PER B737 SRM 53-00-50-2R-7 MATERIAL USED PO#1690453 PO#2039827;[02] CORRECTION TO STEP 1: PERFORMED DRY OUT; PREPARED DAMAGE AREA AND APPLIED PERMANENT REPAIR ON PANEL#231YF AS PER B737 SRM 53-00-50-2R-7 MATERIAL USED PO#1690463 PO#2039827;[03] RII--VERIFIED STEP 1.<BR>AUDIT C/W PER MPM 52.02.02.;[04] RII--VERIFIED STEP 2.<BR>AUDIT C/W PER MPM 52.02.02.