What was found
FWD CARGO COMPT 500I BULKHEAD ANGLE AT FLOOR CORRODED. REMOVED CORROSION AT FWD CARGO COMPT. AFT BULKHEAD LOWER RAIL ANGLE BS 500I, RBL 22 TO LBL 22 IAW SRM 51-10-02. MEASURED REMAINING MATERIAL THICKNESS, OUT OF LIMITS IAW SRM 53-30-08-1A-1 FIG. 103, DETAIL D. REMOVED BULKHEAD ANGLE IAW SRM 51-40-02. DRILLED A NEW ANGLE IAW SRM 51-10-02. DRILLED NEW ANGLE PER SRM 51-10-02.