What was found
FWD CARGO COMPARTMENT FLOOR STRUCTURE AT STA 500I AND RBL 21; HAS STRINGER CLIP UNDER SIDEPLATE CHANNEL WITH CRACKS ORIGINATING FROM FASTENER. (MARKED)<[01] REMOVED FASTENERS; REMOVED RH TRANSITION ANGLE FROM STA 500D+10 TO STA 500I TO FOM PER SRM 51-40-02.<BR>REMOVED DAMAGED STRINGER CLIP FOR REPLACEMENT PER SRM 51-40-02.;[02] LOCATED AND DRILLED CLIP P/N #143A1010-48 (CLIP; CLIP) PER SRM. 51-10-02 OK TO INSTALL;[03] OK TO INSTALL STRINGER CLIP IN FWD CARGO COMPARTMENT FLOOR STRUCTURE AT STA 500I AND RBL 21;[04] REMOVED AND REPLACE STRINGER CLIP AT STA 500I RBL21 PER SRM 51-40-02.;[05] INSPECTED C/A STEP 4; 'REMOVED AND REPLACE STRINGER CLIP AT STA 500I RBL21 PER SRM 51-40-02.';[06] REMOVED AND REPLACED STRINGER CLIP AT STA 500I RBL21 PER SRM 51-40-02.REINSTALLED RH TRANSITION ANGLE FROM STA 500D+10 TO STA 500I PER SRM 51-40-02.;[07] RII. VERIFIED. REMOVED AND REPLACED STRINGER CLIP AT STA 500I RBL21 PER SRM 51-40-02. REINSTALLED RH TRANSITION ANGLE FROM STA 500D+10 TO STA 500I PER SRM 51-40-02.