What was found
FWD CARGO COMPT LH TRANSITION ANGLE CORRODED STA 500A-500B. REMOVED DAMAGE IAW SRM 51-10-02. MEASURED DAMAGE DEPTH TO BE .009. DAMAGE FOUND TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-53-1A-2. CUTOUT & REMOVED DAMAGE SECTION OF TRANSITION ANGLE FROM STA 480+10 TO 500I IAW SRM 53-00-53-2R-5. FABRICATED NEW SECTION OF TRANSITION ANGLEI IAW SRM 53-00-53-2R-5 & EA M-22-153-01550. TREATED & PRIMED REPAIR IAW AMM 51-21-00. INSTALLED BONDED NUT PLATES TO REPAIR IAW SRM 51-40-10. INSTALLED NEW SECTION OF TRANSITION ANGLE IAW SRM 53-00-53-2R-5 & EA M-22-153-01550.