What was found
FWD CARGO COMPT RH TRANSITION ANGLE CORRODED STA 500A-500B<[01] REMOVED CORROSION AT FWD CARGO R/H TRANSITION ANGLE FROM STA 500A TO STA 500I PER SRM 51-10-02. MEASURED BLEND AREAS OUT OF LIMITS PER SRM 53-00-53-1A-2 FIG.103; DETAIL E. STEP 1 FWD CARGO R/H TRANSITION ANGLE; IS OUT OF LIMITS PER SRM 53-30-15-1A-2 FIG. 103; (E).;[03] REMOVED FWD CARGO RH TRANSITION ANGLE STA 500A-500I PER SRM 51-40-02;[04] DRILLED AND COUNTERSUNK R/H NEW TRANSITION ANGLE BS 500A - 500I IAW SRM 51-40-05 AND SRM 51-40-08. INSTALLED TRANSITION ANGLE OUTBOARD RIVETS FROM STA 500A TO 500G PER SRM 51-40-02.