What was found
FWD CARGO COMPT RH SHORT TRANSITION ANGLE AFT OF DOOR CORRODED STA 492-500A<[01] REMOVED CORROSION AT FWD CARGO R/H SHIELD SIDEPLATE ASSY STA 492 TO STA 500A PER SRM 51-10-02. MEASURED REMAINING MATERIAL THICKNESS OUT OF LIMITS PER SRM 53-30-15-1A-1 FIG.103; DETAIL G.;[02] VERIFIED C.A. STEP 1 (AMT C. PAZ) FWD CARGO R/H SHIELD SIDE PLATE ASSY; IS OUT OF LIMITS PER SRM 53-30-15-1A-1 FIG. 103; (G).;[03] DRILLED NEW R/H SHIELD SIDEPLATE IAW SRM 51-40-05.;[04] INSTALLED FWD CARGO R/H SHIELD SIDEPLATE IAW SRM 51-40-02;[05] C/W INSPECTION;[06] C/W INSPECTION