What was found
FWD CARGO COMPARTMENT FLOOR STRUCTURE SIDE PLATE CHANNEL FROM BS 500D TO 500E AT LBL 21; HAS SURFACE CORROSION AT VARIOUS FASTENER HOLES. BLENDED AREAS; REMOVED .010' MATERIAL; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2. REMOVED DAMAGE; TRANSITION ANGLE L/H FROM STA.500E+10 TO STA. 500F+10 ; FABRICATED REPAIR PARTS PER SRM.53-00-53-2R-5. TREATED AND PRIMED PART PER SRM.51-20-02. VERIFIED REPAIR PARTS FABRICATION IAW SRM 53-00-53-2R-5. INSTALLED REPAIRED IAW SRM 53-00-53-2R-5. COMPLIED TAPERED SHIM EA #M-22-153-01550. REMOVED DAMAGE; TRANSITION ANGLE L/H FROM STA.500D+10 TO STA. 500E+10. THE DAMAGE WAS REPAIRED PER SRM 53-00-53-2R-5 (REPAIR 5) AND EAM-22-153-01550.