What was found
FWD CARGO COMPARTMENT FLOOR STRUCTURE SIDE PLATE CHANNEL FROM STA 500E TO STA 500F AT LBL 21; HAS SURFACE CORROSION AT VARIOUS FASTENER HOLES. (MARKED)<[01] BLENDED AREAS; REMOVED .001' MATERIAL; FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-1A-2.;[02] INSPECTED AS REQUIRED. CORRECTIVE ACTION #1;[03] BLENDED AREAS; REMOVED .001' MATERIAL; FOUND TO BE WITHIN LIMITS PER SRM 53-00-53-1A-2. TREATED AND PRIMED PER SRM 51-20-01. THIS SECTION REPLACED ON NR# [TTG8Q00TPHH4];[04] INSPECTED AS REQUIRED. CORRECTIVE ACTION #3