What was found
CRACK LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA95.96 AT LT HORIZONTAL STABILIZER 2024-341174<[01] REPLACED LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA 95.96 AT LT HORIZONTAL STABILIZER IAW B737-700 SRM-51-40-02; SRM-51-10-02 AND DWG 186A1001 SHEET 10 REV. A;[02] CORRECTED STEP 1 REPLACED LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA 95.96 AT LT HORIZONTAL STABILIZER IAW B737-700 SRM-51-40-02; SRM-51-10-02 ITEM 9 AND DWG 186A1001 SHEET 10 REV. A.SEE INDIVIDUAL SIGN OFFS BELOW;[03] REPLACED LEADING EDGE RIB ACCESS PANEL 331B LOCATED LE STA 95.96 AT LT HORIZONTAL STABILIZER IAW B737-700 SRM-51-40-02; SRM-51-10-02 ITEM 9 AND DWG 186A1001 SHEET 10 REV. A.SEE INDIVIDUAL SIGN OFFS BELOW