As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION ON FSD THRESHOLD SUPPORT BS305 - BS324 RBL59 WL208.<[01] VERIFIED CORRECTIVE ACTION ON STEP 1;[02] CORROSION ON FSD THRESHOLD SUPPORT BS 304-324 RBL 59; WL 208 FOUND TO BE OUT OF LIMITS PER SRM 53-10-15-1A-2 REMOVED AND REPLACED FSD THRESHOLD SUPPORT ANGLE IAW SRM 51-40-02-0G-0; SRM 51-40-05-0G-0 AND DWG 141A8310 REV-. ALL OTHER FASTENERS TO BE INSTALLED UPON FSD MOP SILL INSTALLATION.;[03] UPDATED PARTS.;[04] VERIFIED COMPLETION CORRECTIVE ACTION 2 AND MEASUREMENT TABLE.