As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CORROSION AT FLOOR STRUCTURE STABILIZER ANGLE AT STA 927-947.5 LBL-24<[01] REMOVED; FABRICATED; AND INSTALLED NEW ANGLE PN#147A5430-7 AT FLOOR STRUCTURE STA 927-947.5 LBL-24. PER SRM 51-40-02-0G-0 AND BOEING DWG 147A5400 SHEET 21;[02] VERIFIED STEP 1