What was found
LEFT WINGLET/SCIMITAR WRAP AROUND ACCESS PANEL HAS 1EA ELONGATED HOLE<[01] REPAIRED DAMAGE HOLE AT LAFT WINGLET/SCIMITAR WRAP ACCESS PANEL AS PER SRM 51-70-04-2R-9. MATERIAL USED EA9390 PO #2061896.<BR>PERFORMED ULTRASOUND INSPECTION OF REPAIRED AREA AND MINIMUM OF 6 INCHES ALL AROUND USING CONTACT THROUGH TRANSMISSION ULTRASONIC REF B737 NDT PT 1; 51-01-01; NDT PT4 51-00-02. NO DAMAGE NOTED<BR> TOOL: EPOCH 650 B/C: 168106 DUE: 12/11/24;[02] VERIFIED STEP 1.