What was found
CRACK ENTRY DOOR CUT OUT WEB INTERCOSTAL AT S-16L AND BETWEEN STA294.5 TO STA 303.9 AT FWD GALLEY AREA 2024-361693<[01] REPLACED INTERCOSTAL AND FASTENERS LOCATED BTW BSTA 294.5 TO BSTA 303.9 AT STR 16L. AT FWD GALLEY AREA. IAW B737-700 SRM 51-10-02. PARAGRAPH 9. DWG# 141A8180 SHEET 27 REV. ?C?. AND SHEET 28. REV. ?C?. SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED INTERCOSTAL AND FASTENERS LOCATED BTW BSTA 294.5 TO BSTA 303.9 AT STR 16L. AT FWD GALLEY AREA. IAW B737-700 SRM 51-10-02. PARAGRAPH 9. DWG# 141A8180 SHEET 27 REV. ?C?. AND SHEET 28. REV. ?C?. SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII CERTIFIED