What was found
(A-221 DOT 38); FWD WET AREA L1 DOOR IS SAGGING/ FAILED GAP CHECK BETWEEN DOOR AND DOOR SKIN CUTOUT<[01] REMOVED AND REPLACED UPPER AND LOWER SERRATED PLATE ASSEMBLIES; AND GUIDE ARM IAW SRM 51-40-02-0G-0 AND TASK CARD 752-RCB-01-01 FAULT TTG8R007P3ND. L1 DOOR WAS REMOVED; REINSTALLED; AND RIGGED ON ON FAULT TTG8Q00U7G8R;[02] REMOVED AND REPLACED UPPER AND LOWER SERRATED PLATE ASSEMBLIES; AND GUIDE ARM IAW SRM 51-40-02-0G-0 AND TASK CARD 752-RCB-01-01 FAULT TTG8R007P3ND. L1 DOOR WAS REMOVED; REINSTALLED; AND RIGGED ON ON FAULT TTG8Q00U8CBY;[03] VERIFIED STEP 2<BR>AUDIT CW