REJECT - IMPROPERLY WEB REPAIR PROCEDURE AT RT HORIZONTAL STABILIZER (TRIMMED OUT WEB INSTEAD STOP DRILL PROCEDURE) 2024-345807<[01] FOR STEP 2; TOOL USED: EDDY CURRENT FLAW DETECTOR; P/N: NORTEC 600D; S/N:190023010; DUE DATE: 24-JUL-24;[02] REPAIRED FRONT SPAR WEB LOC. BETWEEN STAB STA 138.70 TO STAB STA 147.90 AT RT HORIZONTAL STABILIZER IAW B737-700 EA 24-155-01688-WIP1; SRM B737-700 55-10-10-2R-1. SEE INDIVIDUAL SIGN OFFS BELOW.;[03] CORRECTED STEP 2: REPAIRED FRONT SPAR WEB LOC. BETWEEN STAB STA 138.70 TO STAB STA 147.90 AT RT HORIZONTAL STABILIZER IAW EA 24-155-01688-WIP1; EA# EA 24-155-01688 AND SRM B737-700 55-10-10-2R-1.<BR> SEE INDIVIDUAL SIGN OFFS BELOW.;[04] CERTIFIED RII MAJOR REPAIR WORK PERFORMED. <BR>SEE INDIVIDUAL SIGN OFF BELOW.