What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328; RBL 31 FWD GALLEY AND LAV 2024-393044<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328; RBL 31 FWD GALLEY AND LAV IAW. B737-700 SRM 51-10-02-0G-0; 51-40-02-0G-0 AND DRAWING 141A5400 REV -.;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 AND BS 328; RBL 31 FWD GALLEY AND LAV IAW. B737-700 SRM 51-10-02-0G-0; 51-40-02-0G-0 AND DRAWING 141A5400 REV -. SEE INDIVIDUAL SIGN OFF BELOW;[03] TASK COMPLETED<BR><BR>SEE INDIVIDUAL SIGNOFFS BELOW