What was found
MAIN CABIN L/H; FLOOR STRUCTURE AT STA 540; LBL1 AFT; FOR PANEL 231XF; PANEL BREAK ANGLE IS BROKEN AT HI-LOK ATTACHMENT POINT. HAECO DOT A084<[01] REMOVED AND REPLACED BREAK ANGLE PN: 143A5240-33 PO:1094583.1 IAW B737NG-SRM 51-40-02 AND BAC DWG 143A0060 REV:-;[02] REMOVED AND REPLACED BREAK ANGLE PN: 143A5240-33 PO:1094583.1 IAW B737NG-SRM 51-40-02 AND BAC DWG 143A0060 REV:-;[03] VERIFIED REMOVED AND REPLACED BREAK ANGLE PN: 143A5240-33 PO:1094583.1 IAW B737NG-SRM 51-40-02 AND BAC DWG 143A0060 REV:-