What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS290 BL0 WL208.<[01] REMOVED AND INSTALLED NEW INTERCOSTAL BETWEEN BS 277 TO BS 294 BL 0 WL 208 PER SRM 51-40-05 AND DWG 141A5400;[02] VERIFIED ACTION 1.;[03] UPDATED MEASUREMENTS;[04] REJECT: DURING VERIFICATION OF INTERCOSTAL INSTALLATION; STRAPS (3 E/A) WERE FOUND INSTALLED INCORRECTLY OVER INTERCOSTAL WITH NO SUPPORT OF TECHNICAL DOCUMENTATION. [TTG8Q00UD5X3];[05] REMOVED AND REPLACED NEW INTERCOSTAL BETWEEN BS 277 TO BS 294; BL 0; WL 208 PER SRM 51-40-02-0G-0; AND DWG 141A5400;[06] VERIFIED CORRECTIVE ACTION 5