What was found
CORROSION ON FLOOR SUPPORT AT AFT WET AREA BS947+4 RBL46 WL208.<[01] REMOVED AND REPLACED FLOOR SUPPORT ANGLE FROM BS 947 TO BS 967; RBL-46; WL-208 IAW SRM 51-40-02-0G-0 AND DWG# 147A5760;[02] VERIFIED CORRECTIVE ACTION #1
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOOR SUPPORT AT AFT WET AREA BS947+4 RBL46 WL208.<[01] REMOVED AND REPLACED FLOOR SUPPORT ANGLE FROM BS 947 TO BS 967; RBL-46; WL-208 IAW SRM 51-40-02-0G-0 AND DWG# 147A5760;[02] VERIFIED CORRECTIVE ACTION #1