What was found
PASSENGER CABIN FLOOR BEAM AT APPROX. BS987 LBL 43 HAS CORROSION AROUND HOLE. REMOVED DAMAGE. FOUND TO BE OUT OF LIMITS PER SRM 53-70-51-1A-1. CUT AND REMOVED DAMAGED PART OF FLOORBEAM IAW SRM 53-70-51-2R-6 REPAIR 6 ALTERNATIVE 4. NDT PART 6;51-00-00 PROCEDURE 16. FABRICATED/DRILLED ANGLE AND STRAP PER SRM 53-70-51-2R-6. FLAP PEENED AREA PER SRM 53-70-51-2R-6 AND SOPM 20-10-03. FABRICATED FILLER IAW SRM 53-70-51-2R-6. TREATED & PRIMED PER SRM 51-20-01. INSTALLED REPAIR PARTS ON FLOORBEAM IAW SRM 53-70-51-2R-6.