What was found
CORROSION ON FWD CARGO COMPARTMENT RH SIDE PLATE BETWEEN STA. 500A-500B.(MARKED)<[01] BLENDED AREAS REMOVED .005' MATERIAL; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[02] LOCATED AND DRILLED NEW TRANSITION ANGLE P/N #143A7501U188 PER SRM 51-40-05 ;OK TO INSTALL;[03] VERIFIED C/A # 1 : ROBERT DENSFORD (TECHNICIAN); 03-JUL-2024 12:01 UTC<BR>BLENDED AREAS REMOVED .005' MATERIAL; FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[04] VERIFIED C/A 2 : TONY NGUYEN (TECHNICIAN); 03-JUL-2024 14:10 UTC<BR>LOCATED AND DRILLED NEW TRANSITION ANGLE P/N #143A7501U188 PER SRM 51-40-05 ;OK TO INSTALL;[05] GRANTED OK TO INSTALL REPLACE SECTION FROM STA 500A TO STA 500 I;[06] REMOVED AND REPLACED RH SIDE PLATE FROM STA 500A TO STA 500I PER SRM 53-00-53-1A-2;AND SRM 51-40-02.;[07] 02 - INSPECTED PER [SRM 53-00-53-1A-2-B00297 (PERMANENT (NON-DENT DAMAGE TYPES))]