What was found
(#151-005) CORROSION ON FLOOR TO SIDEWALL SUPPORT IN FWD CARGO AT B.S 500 F+1 INCH; LBL 24; WL156.<[01] REMOVED CORROSION ON FLOOR TO SIDEWALL SUPPORT IN FWD CARGO AT B.S 500F+1 INCH; LBL 24; WL 156. EVALUATED MATERIAL LOSS AND FOUND ORIG 'T' .040'; REMAINING .034'; LOSS OF .006'. FOUND TO BE OUT OF LIMITS. Z-ANGLE REMOVED AND REPLACED ON W/O TTG8Q00ULT3J;[02] VERIFIED C/W;[03] AUDIT C/W