What was found
FWD GALLEY HEADER PANEL AND G1 GALLEY EMERGENCY EXIT LIGHTS INOP<[01] TROUBLESHOOTING NOTES - ISSUES ARE SUSPECTED TO BE CONFINED TO WIRING ASSOCIATED BETWEEN P18-3 A11 (C0250) AND BATTERY PACK M2816.<BR>- VOLTAGE READING FROM (C0250) TO (D14812P): PIN22=1.0VDC; PIN2=0.6VDC; PIN9=25VDC; PIN11=25VDC; PIN12=0.0VDC; PIN14=24VDC; PIN15=25VDC.<BR>- CONTINUITY READING FROM (C0250) TO (D14812P): PIN22=0.0OHMS; PIN2=0.0OHMS.<BR>- CONTINUITY READING FROM (D14812P) TO (GND) 'THROUGH LIGHT': PIN9=6.0OHMS; PIN11=7.8OHMS; PIN14=5.0OHMS; PIN15=6.0OHMS.<BR>-ALREADY REPLACED ALL 4 FUSES; ATTEMPTED BATTERY SWAP; RE-LAMPED LIGHTS.<BR>-ADDITIONAL TROUBLESHOOTING REQUIRED.;[02] TESTED SYSTEM PER AMM 33-51-00-710-801 AND WDM 33-51-12; FOUND THAT ALL INOPERATIVE LIGHTS WERE POWERED BY M2816. DETERMINED THAT BATTERY CHARGER WAS FAULTY; SINCE IT WOULD NOT CHARGE A KNOWN GOOD BATTERY; CAUSING BATTERY FAILURE DUE TO EXCESSIVE TIME OFF CHARGER. REPLACED AND TESTED M2816 EMERGENCY BATTERY AND M2816 BATTERY CHARGER PER AMM 33-51-06-960-805 AND AMM 33-51-06-960-806; NO DEFECTS NOTED.;[03] CORRECTION TO CORRECTIVE ACTION 1. VOLTAGE AND CONTINUITY CHECKS DONE FOR M2816 ARE DONE PER WDM 33-51-12 AND METER USED:<BR>MULTIMETER<BR>CAL ID:PER2060; DUE DATE:09/2024<BR>REPLACEMENT OF 4 FUSES FOR M2816 USED AMM 33-51-06-960-801<BR>NO MORE TROUBLESHOOTING REQUIRED ACTION STEP 2 RESOLVED THE DISCREPANCY.;[04] VERIFIED.