What was found
CORROSION ON STRAP LOCATED BETWEEN BS 1006 TO BS 1016 AND LBL 6 WL 208.1 AT AFT GALLEY AREA. 2024-443524<[01] REPLACED STRAP AND FASTENERS LOCATED BETWEEN BS 1006 TO BS 1040 LBL 6 WL 208.1 AFT GALLEY AREA IAW B737-700 SRM 51-10-02 PARAGRAPH 9 AND SRM 51-40-02 AND DWG 147A5600 SHEET 44 REV: C.<BR>SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED STRAP AND FASTENERS LOCATED BETWEEN BS 1006 TO BS 1040 LBL 6 WL 208.1 AFT GALLEY AREA IAW B737-700 SRM 51-10-02 PARAGRAPH 9 AND SRM 51-40-02 AND DWG 147A5600 SHEET 44 REV: C.<BR>SEE INDIVIDUAL SIGN OFF BELOW.