What was found
CRACK ON STUB FRAME LOCATED BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA 2024-420826<[01] TOOL USED ON STEP 5 AND 6: EDDY CURRENT EQUIPMENT P/N: NORTEC 600D; S/N: 220273012; DUE DATE: 09-JAN-25;[02] REPAIRED STUB FRAME LOCATED ON BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA. I.A.W. B737-700 SRM 53-10-15-2R-7; REPAIR 7. NO FURTHER ACTION OR INSPECTION REQUIRED.<BR>SEE INDIVIDUAL SIGN OFF BELOW;[03] REPAIRED STUB FRAME LOCATED ON BS 294.5 AT LEVEL STR 17R AT FWD GALLEY AREA. I.A.W. B737-700 SRM 53-10-15-2R-7; REPAIR 7. NO FURTHER ACTION OR INSPECTION REQUIRED.<BR>SEE INDIVIDUAL SIGN OFF BELOW<BR>TASK RII CERTIFIED