What was found
CORROSION FLOOR STRUCTURE BEAM LOCATED BS986.5; RBL 43; WL208.1 AFT GALLEY AND LAV 2024-458670<[01] TOOL USED IN STEP 5: UT EQUIPMENT; P/N: 45MG; S/N: 130064101 DUE DATE: 13-DEC-25;[02] TOOL USED ON STEP 9: EDDY CURRENT EQUIPMENT; P/N: NORTEC 600D; S/N: 200053402; DUE DATE: 24-AUG-24;[03] TOOL USED ON STEP 13 ET EQUIPMENT: P/N: NORTEC 600D; S/N: 220272512; CAL DUE DATE: 08-JAN-25;[04] PERFORMED PERMANENT REPAIR ON FLOOR BEAM LOCATED BS986.5; RBL43; WL208.1 AFT GALLEY IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 SEE INDIVIDUAL SIGN OFF BELOW;[05] PERFORMED PERMANENT REPAIR ON FLOOR BEAM LOCATED BS986.5; RBL43; WL208.1 AFT GALLEY IAW B737-700 SRM 53-70-51-2R-6 REPAIR 6 SEE INDIVIDUAL SIGN OFF BELOW ;Ï¿½TEM RII