What was found
FWD ENTRY DOOR CUTOUT SURROUND STRUCTURE; INTERCOSTAL BS 303.9+8 S-6L HAS CRACK.<[01] HFEC INSPECTED FRAME AT BS 303.9+8' STR 6L PER 737NDT PART 6 51-00-00 PROCEDURE 23. FOUND CRACK ON EDGE OF EXISTING TRIM OUT. MARKED END OF CRACK WITH BLACK SHARPIE; CRACK MEASURES .130' IN LENGTH FROM EDGE. REMOVED CRACK BY 0.150' ON THE EXISTING TRIM OUT RADIUS AT BS 303.9+8' STR 6L IAW SRM 51-10-02. HFEC INSPECTED CUT-OUT AREA IAW 737 NDTM PART 6; 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR>EQUIP USED: -NORTEC 600 ID: ATS2353 CAL DUE: 01/2025;[02] VERIFIED CORRECTIVE ACTION STEP 1.