What was found
CRACK INDICATION FOUND ON LT HORIZONTAL STABILIZER LOWER SKIN PANEL. LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB. CRACK LENGTH = 0.450 INCH. APPROX. 2024-454383<[01] ON STEP 6; TOOL USED P/N: NORTEC 500D; S/N: 500X1693P030457; CAL DUE: 15-OCT-24.;[02] PERFORMED PERMANENT REPAIR LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB IAW EA-24-155-02268 WIP1 AND EA- 24-155-02268-SUMMARY SEE INDIVIDUAL SIGN OFFS BELOW.;[03] TASK COMPLETED CERTIFIED RII<BR>PERFORMED PERMANENT REPAIR LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB IAW EA-24-155-02268 WIP1 AND EA- 24-155-02268-SUMMARY SEE INDIVIDUAL SIGN OFFS BELOW.